Chinese Journal of Biologicals ; (12): 352-2023.
Article in Chinese | WPRIM | ID: wpr-976126

ABSTRACT

@#Objective To develop and verify a method for determination of cyanide residues in polysaccharide-protein conjugate vaccines based on flow injection analysis(FIA)with amperometric detector.Methods After removing macromolecular substances in the samples by ultrafiltration,the cyanide residues were determined by a 3700 automatic chemical analyzer with the injection time of 35 s,injection volume of 200 μL,pump speed of 40%,sample cycle time of 140 s,ultraviolet wavelength of 312 nm and an Ampere detector.The developed method was verified for the specificity,matrix effect,linear range,limit of detection(LOD),limit of quantitation(LOQ),accuracy,presicion and stability.The cyanide residues in the polysaccharide derivative bulk(13 batches)and conjugate bulk(21 batches)of Haemophilus influenzae type b conjugate vaccine and group A and C meningococcal conjugate vaccine produced by 5 manufacturers were determined by the developed method.Results Blank samples showed no interference to detection;The recoveries of the matrix effector solution of Haemophilus influenzae type b conjugate vaccine polysaccharide derivative and conjugate bulk,group A and C meningococcal conjugate vaccine polysaccharide derivative and conjugate bulk were 97.4%,102.4%,96.8% and 99.8% respectively,with all CV values less than 15%;In the range of 0.312 5 ~ 80 ng/mL,cyanogroup concentration showed a good linear relationship with peak height with a regression equation of y = 133.13 x + 57.556,R2= 0.999 1;The LOD was 0.2 ng/mL,and the LOQ was 0.6 ng/mL.The average recoveries of the control solution were 108.9%,106.5%,103.5% respectively with RSD value of 6.4% in the groups added with 5,10 and 20 ng/mL of cyanogroup and the CV values of precision verification were all less than 15%;The average concentrations of the control solution injected 20 times continuously were 76,38,18and 5 ng/mL with all CV values less than 15%,when cyanogroup concentration was 80,40,20 and 5 ng/mL,respectively.Cyanide residues were detected in 13 batches of derivative bulk samples,while not in 2 batches of 21 batches of polysaccharide conjugate bulk samples,and were detected in the others.Conclusion The developed method had good accuracy,precision and stability,which might be applied to the quantitative determination of cyanide residues in polysaccharideprotein conjugate vaccines.

SELECTION OF CITATIONS
SEARCH DETAIL